Conventional Pollution Online Monitoring Instrument
Ultraviolet COD Online Analyzer
product details

Product model: CODUV-8000

 

System Overview

 

UV method, also known as ultraviolet COD online analyzer, can achieve rapid, accurate and economical online determination of COD in water samples. The basic measurement principle of the instrument is based on the absorption of ultraviolet light by organic matter in sewage. Organic compounds containing conjugated double bonds or polycyclic aromatic hydrocarbons can absorb ultraviolet light when dissolved in water. Therefore, by measuring the absorption of ultraviolet light by these organisms, we can assess the extent to which the water is polluted by these organisms. Application areas include drinking water, surface water, industrial process water, sewage treatment and other fields. It can be used to continuously monitor the organic pollution degree of raw water and sewage plant imports and the removal rate of organic matter in the treatment process, as well as the organic pollution degree of industrial circulating water.

 

Technical Parameters

 

Test method: ultraviolet method;
Test range: COD: 0 ~ 200/500/1000mg/L;
SAC: 0 ~ 300/750/1500;
Zero drift: <±5%;
Range drift: <±10%;
Accuracy: < 10%;
Reproducibility: < 5%;
Response time: min 5min;
Test mode: timing, equal interval, manual;
Reagent consumption: no need for any chemical reagents, no secondary pollution;
Maintenance mode: self-maintenance, user maintenance interval >5 months;
Self-monitoring: self-diagnosis of instrument status;
Analog output: 4– 20mA analog output;
Relay control: 2 24V 1A relay high and low point control;
Data transmission mode: RS232, RS485;
Display: 8-inch LCD touch screen, resolution 800×600;
Data storage: five years of valid data;
Operating temperature: +0 ~ +40°C;
Power supply: 220 ±10% VAC; 50-60Hz;
Power consumption: about 100 VA;
Size: 530×1340×390mm;
Weight: about 45Kg.

Product Features

 

· The water sample pretreatment device adopts maintenance-free design, which can ensure that the maintenance cycle of the pretreatment device exceeds half a year.

· The measurement process is completed in an instant, and the measurement process and results meet the relevant international standards.

· The analytical flow path design of all imported devices ensures the measurement reproducibility, which can reach 5% at present.

· Automatic operation, no personnel on duty, can achieve automatic zero, automatic calibration, automatic measurement, automatic cleaning, automatic maintenance, self-protection, automatic recovery and other intelligent functions.

· Online monitoring methods are diversified, which can realize manual measurement at any time, automatic timing measurement, automatic periodic measurement and other measurement methods.

· Do not need any chemical reagents, do not produce any secondary pollution, to achieve a real sense of COD real-time online monitoring.