Drinking Water Online Monitoring Instrument
Online Reactive Oxygen Analyzer
product details

Product Model: ROS900

 

Measurement Methods

 

induced fluorescence method or colorimetric method.

A variety of options can be realized

Timing measurement can be realized every day at any time the user wants to monitor the instrument to start measurement; Isochronous measurement can automatically start the instrument for measurement every few hours at a fixed time interval every day; Continuous measurement can realize automatic sample measurement one by one, which can be used for product acceptance and related technical certification; Manual measurement can realize the user to start the measurement at any time, and can be used for field experiment comparison and equipment installation and debugging.

 

Technical Parameters

 

Measuring range: 0-2mg /L;
Measurement accuracy: 10%;
Repeatability: 5%;
Zero drift: 5%;
Range drift: 10%;
MTBF (trouble-free running time) : ≥720 h/ time;
Measurement time: minimum 15min;
Correction mode: automatic timing correction or manual correction;
Reagent consumption: only 2mL of each reagent is consumed per measurement;
Sampling inside the instrument: injection pump is used, which has a long life compared with peristaltic pump;
Secondary pollution: the chemical reagents used are recycled, there is no direct emission;
Data transmission: 4-20 mA, RS232, etc.
Ambient temperature: +5°C to +40°C;
Mechanical size: 530×1340×390mm;
Weight: about 45 kg;
Power supply: (220±20) VAC /(50±0.5) Hz;
Power consumption: about 100 W.

Advantage

 

Easy to oPerate

Integrated report generation, real-time monitoring of the whole reaction process, and dynamic display of the test project response curve.

 

Flexible Detection

The measurement period is short, the response speed is fast, and the detection process can be set freely.

 

Quality Control and Calibration

Automatic quality control and calibration to ensure the consistency and reliability of test results.

 

Fully Automatic Control

The user can program the detection parameters to adapt to different applications, automatically start the cyclic detection mode for suspicious samples, and start the control center alarm when the machine calls again after power failure, automatically resume the working state.

 

Reliable Operation

Low cost of use and maintenance, automatic completion of sample and reagent dispensing, mixing and cleaning, avoid cross-contamination, easy maintenance, low operating cost, small reagent consumption, weekly maintenance, only need to replace reagents, disposable consumables cost is low.