- Conventional Pollution Online Monitoring Instrument
- Drinking Water Online Monitoring Instrument
- Special Parameter Online Monitoring Instrument
- Heavy Metal Online Monitoring Instrument
- Industrial Process Water Online Monitoring Instrument
- Anodic Stripping Voltammetry Heavy Metal Monitoring Instrument
- Laboratory Online Testing Instrument
- Water Treatment Process Instruments
Product model: TMg-8000
Measurement Method
Ultraviolet digestion, characteristic color determination, can accurately measure the total amount of magnesium ions in surface water, groundwater and industrial wastewater.
A variety of Options Can Be Realized
Timing measurement can be realized every day at any time the user wants to monitor the instrument to start measurement;
Isochronous measurement can automatically start the instrument for measurement every few hours at a fixed time interval every day;
Continuous measurement can realize automatic sample measurement one by one, which can be used for product acceptance and related technical certification;
Manual measurement can realize the user to start the measurement at any time, and can be used for field experiment comparison and equipment installation and debugging.
Technical Parameters
Measuring range: | 1-500/1000mg/L; |
Measurement accuracy: | <10%; |
Repeatability: | <5%; |
Zero drift: | ±0.05mg/L; |
Range drift: | ±10%; |
MTBF (trouble-free running time) : | ≥720 h/ time; |
Actual water sample comparison error value: | ±10%; |
Measurement time: | 15-60min can be set arbitrarily; |
Ultraviolet digestion method: | the ultraviolet digestion technology is adopted, through which the measurement time can be shortened; |
Digestion time: | 5-60min, can be set arbitrarily; |
Data transmission: | provide 4-20 mA, RS232, RS485, GPRS and other data transmission interfaces; |
Ambient temperature: | +5°C to +40°C; |
Mechanical size: | 590×700×360mm; |
Weight: | about 35 kg; |
Power supply: | (220±20) VAC /(50±0.5) Hz; |
Power consumption: | about 100W. |
System Features
· Maintenance Free Design
The water sample pre-treatment device adopts a maintenance free design, which can ensure that the maintenance cycle of the pre-treatment device exceeds six months;
· Chemical Digestion Time Can Be Adjusted
The chemical digestion time can be adjusted, and the measurement process and results meet relevant standards;
· Adjustable Quantitative Sampling Device
Ensure that the instrument accurately measures various water samples by adjusting the reagent dosage and sampling amount;
· Non Contact Injection Pump
The use of reagents adopts a non-contact injection pump to avoid direct corrosion of the reagent pump, which can extend the service life of core components and reduce user usage costs;
· All Imported Devices
The analysis of flow path design and reagent formulation ensures measurement reproducibility, with a current measurement reproducibility of up to 5%;
· Fully Automatic Operation
No need for personnel on duty, it can achieve intelligent functions such as automatic zero adjustment, automatic calibration, automatic measurement, automatic cleaning, automatic maintenance, self-protection, and automatic recovery;
· Diversified Online Monitoring Methods
It can achieve measurement methods such as manual measurement at any time, automatic timed measurement, and automatic periodic measurement;
· Leakage Reminder Function
When there is a reagent leak, the instrument automatically prompts the user to perform maintenance.