Product Model: T8000-Cl
Measuring Method
Characteristic chromogenic assay,this method can accurately determine the total amount of chloride in surface water, groundwater and industrial wastewater.
Technical Parameters
Measurement range: | 1-5000mg/L; |
Measurement accuracy: | <10%; |
Repeatability: | <5%; |
Zero drift: | ±0.5mg/L; |
Range drift: | ± 10%; |
MTBF (Time between failures): | ≥ 720 hours per occurrence; |
Actual water sample comparison error value: | ± 10%; |
Measurement time: | 15-60 minutes can be set arbitrarily; |
Reaction time: | 5-60 minutes, can be set arbitrarily; |
Data transmission: | 4-20 mA, RS232, RS485, etc; |
Environmental temperature: | +5 ° C to+40 ° C; |
Size: | 530x1340x390mm; |
Weight: | approximately 45kg. |
Power supply: | (220 ± 20) VAC/(50 ± 0.5) Hz. |
Power consumption: | approximately 100 W. |
Benefits
A Variety of Measurement Methods Can Be Realized
Timed measurement can enable users to start the instrument for measurement at any time they want to monitor every day; Isochronous measurement can automatically start the instrument every few hours at fixed time intervals every day for measurement; Continuous measurement can achieve automatic sample measurement one after another, which can be used for product acceptance and related technical certification; Manual measurement can enable users to start measurement on-site at any time, and can be used for on-site experimental comparison and equipment installation and debugging.
Measuring Time Can Be Arbitrarily Set
It can ensure that any water sample can react completely, and the setting of measurement time ensures that any water sample can accurately obtain detection results through the instrument.
Flexible Calibration of Standard Solutions
Automatic timing calibration or manual calibration, where the calibration standard solution can be configured and set according to the actual bromate content range of the user’s water sample according to the principle of proximity, because the water sample that the user wants to monitor is generally limited to a certain range. The instrument can adjust the accuracy of the measurement by preparing a standard solution that is close to the actual bromate content of the user’s water sample according to the principle of proximity.
Fuel Injection Pump Long Service Life
The syringe only needs to be replaced once a year.
Low reagent consumption
Each measurement only consumes 1mL of each reagent.
Diversified Online Monitoring Methods for Instruments
Implement measurement methods such as manual measurement at any time, automatic timed measurement, and automatic periodic measurement.